CigarCity Softwash
Remote Start/Stop System for P40 Gas Roof Pumps/Pressure Washers – Compatible with Honda GX160, GX200, GX390,
Product Overview
This Remote Start/Stop System is designed for contractors who want simple and reliable wireless control over their gas-powered roof pumps. Engineered to work with any Honda GX160, GX200, or GX390 engine that already has an electric start, this system allows you to remotely shut down the engine and restart it at the push of a button. Ideal for softwash systems, roof cleaning setups, and trailer or skid-mounted rigs needing operator convenience and increased efficiency.
Key Features
-
Wireless remote on/off functionality
-
Compatible with Honda GX160, GX200, and GX390 engines
-
Requires an electric-start engine to enable remote restart
-
Plug-and-play style installation
-
Reliable long-range remote performance
-
Durable, weather-resistant components
-
Designed for professional softwashing and roof cleaning setups
- Includes (3) wires to control a Teejet off Button B.
Specifications
-
Function: Remote Start/Stop (simple on/off only)
-
Compatibility: Honda GX160 / GX200 / GX390
-
Requirement: Electric start is required for remote restart
-
Application: Gas-powered roof pumps, softwash systems, trailer rigs, skid systems
-
Included: Wireless receiver module, handheld remote, wiring harness
Product Benefits
-
Reduce trips back and forth to your equipment
-
Increase efficiency when alternating between multiple cleaning tasks
-
Improve workflow on large roof cleaning or softwashing jobs
-
Extend engine life by allowing instant shutdown when not in use
Wiring Connections / Button Layout
- A = Stop
- B = Chemical Flush
- C = Engine Start
- D = Unused
Installation Instructions
- Connect red wire with ring terminal to battery positive side of solenoid on P40.
- Connect black wire with ring terminal to grounding point on engine, such as the screw that holds the solenoid to the block.
- T-Tap the yellow wire coming out of the side of the engine block then connect the yellow wire in the harness to the T-Tap.
- Disconnect the black/white wire from the center of the solenoid and insert the green wire spade connector. Once connected, install the black/white wire into the additional spade connection.
Secondary Harness
In addition to the primary harness, there is a secondary 3 wire harness that can control a TeeJet 12v Valve off Button Channel B. To install, connect the black wire to the solenoid ground, red wire to solenoid positive and white wire to the solenoid trigger wire. These wires will match up to all TeeJet units coloring wise.